Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 55
Filtrar
1.
Clin Chem Lab Med ; 2024 Apr 04.
Artículo en Inglés | MEDLINE | ID: mdl-38564801

RESUMEN

OBJECTIVES: Secretoneurin (SN) is a novel cardiac biomarker that associates with the risk of mortality and dysfunctional cardiomyocyte Ca2+ handling in heart failure patients. Reference intervals for SN are unknown. METHODS: SN was measured with a CE-marked ELISA in healthy community dwellers from the fourth wave of the Trøndelag Health Study (HUNT4) conducted in 2017-2019. The common, sex and age specific 90th, 95th, 97.5th and 99th percentiles were calculated using the non-parametric method and outlier exclusion according to the Reed test. The applicability of sex and age specific reference intervals were investigated using Harris and Boyd test. We also estimated the percentiles in a subset with normal findings on echocardiographic screening. RESULTS: The total cohort included 887 persons (56.4 % women). After echocardiographic screening 122 persons were excluded, leaving a total of 765 persons (57.8 % women). The 97.5th percentile (95 % CI in brackets) of SN was 59.7 (57.5-62.1) pmol/L in the total population and 58.6 (57.1-62.1) pmol/L after echocardiography screening. In general, slightly higher percentiles were found in women and elderly participants, but less than 4 % in these subgroups had concentrations deviating from the common 97.5th percentile. Low BMI or eGFR was also associated with higher concentrations of SN. CONCLUSIONS: Upper reference limits for SN were similar amongst healthy adult community dwellers regardless of prescreening including cardiac echocardiography or not. Women and elderly showed higher concentrations of SN, but the differences were not sufficiently large to justify age and sex stratified upper reference limits.

2.
Clin Biochem ; 125: 110731, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38360198

RESUMEN

BACKGROUND: An analytical benchmark for high-sensitivity cardiac troponin (hs-cTn) assays is to achieve a coefficient of variation (CV) of ≤ 10.0 % at the 99th percentile upper reference limit (URL) used for the diagnosis of myocardial infarction. Few prospective multicenter studies have evaluated assay imprecision and none have determined precision at the female URL which is lower than the male URL for all cardiac troponin assays. METHODS: Human serum and plasma matrix samples were constructed to yield hs-cTn concentrations near the female URLs for the Abbott, Beckman, Roche, and Siemens hs-cTn assays. These materials were sent (on dry ice) to 35 Canadian hospital laboratories (n = 64 instruments evaluated) participating in a larger clinical trial, with instructions for storage, handling, and monthly testing over one year. The mean concentration, standard deviation, and CV for each instrument type and an overall pooled CV for each manufacturer were calculated. RESULTS: The CVs for all individual instruments and overall were ≤ 10.0 % for two manufacturers (Abbott CVpooled = 6.3 % and Beckman CVpooled = 7.0 %). One of four Siemens Atellica instruments yielded a CV > 10.0 % (CVpooled = 7.7 %), whereas 15 of 41 Roche instruments yielded CVs > 10.0 % at the female URL of 9 ng/L used worldwide (6 cobas e411, 1 cobas e601, 4 cobas e602, and 4 cobas e801) (CVpooled = 11.7 %). Four Roche instruments also yielded CVs > 10.0 % near the female URL of 14 ng/L used in the United States (CVpooled = 8.5 %). CONCLUSIONS: The number of instruments achieving a CV ≤ 10.0 % at the female 99th-percentile URL varies by manufacturer and by instrument. Monitoring assay precision at the female URL is necessary for some assays to ensure optimal use of this threshold in clinical practice.


Asunto(s)
Infarto del Miocardio , Humanos , Masculino , Femenino , Estudios Prospectivos , Canadá , Infarto del Miocardio/diagnóstico , Bioensayo , Troponina , Troponina T , Biomarcadores , Valores de Referencia
3.
Clin Chem Lab Med ; 62(4): 729-739, 2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-37937808

RESUMEN

OBJECTIVES: Chronic myocardial injury (CMI) is defined as stable concentrations of cardiac troponin T or I (cTnT or cTnI) above the assay-specific 99th percentile upper reference limit (URL) and signals poor outcome. The clinical implications of diagnosing CMI are unclear. We aimed to assess prevalence and association of CMI with long-term prognosis using three different high-sensitivity cTn (hs-cTn) assays. METHODS: A total of 1,292 hospitalized patients without acute myocardial injury had cTn concentrations quantified by hs-cTn assays by Roche Diagnostics, Abbott Diagnostics and Siemens Healthineers. The median follow-up time was 4.1 years. The prevalence of CMI and hazard ratios for mortality and cardiovascular (CV) events were calculated based on the URL provided by the manufacturers and compared to the prognostic accuracy when lower percentiles of cTn (97.5, 95 or 90), limit of detection or the estimated bioequivalent concentrations between assays were used as cutoff values. RESULTS: There was no major difference in prognostic accuracy between cTnT and cTnI analyzed as continuous variables. The correlation between cTnT and cTnI was high (r=0.724-0.785), but the cTnT assay diagnosed 3.9-4.5 times more patients with having CMI based on the sex-specific URLs (TnT, n=207; TnI Abbott, n=46, TnI Siemens, n=53) and had higher clinical sensitivity and AUC at the URL. CONCLUSIONS: The prevalence of CMI is highly assay-dependent. cTnT and cTnI have similar prognostic accuracy for mortality or CV events when measured as continuous variables. However, a CMI diagnosis according to cTnT has higher prognostic accuracy compared to a CMI diagnosis according to cTnI.


Asunto(s)
Síndrome Coronario Agudo , Masculino , Femenino , Humanos , Pronóstico , Síndrome Coronario Agudo/diagnóstico , Troponina T , Troponina I , Bioensayo , Biomarcadores
4.
Clin Chem ; 70(3): 497-505, 2024 03 02.
Artículo en Inglés | MEDLINE | ID: mdl-38102065

RESUMEN

BACKGROUND: Cardiac troponin measurements are indispensable for the diagnosis of myocardial infarction and provide useful information for long-term risk prediction of cardiovascular disease. Accelerated diagnostic pathways prevent unnecessary hospital admission, but require reporting cardiac troponin concentrations at low concentrations that are sometimes below the limit of quantification. Whether analytical imprecision at these concentrations contributes to misclassification of patients is debated. CONTENT: The International Federation of Clinical Chemistry Committee on Clinical Application of Cardiac Bio-Markers (IFCC C-CB) provides evidence-based educational statements on analytical and clinical aspects of cardiac biomarkers. This mini-review discusses how the reporting of low concentrations of cardiac troponins impacts on whether or not assays are classified as high-sensitivity and how analytical performance at low concentrations influences the utility of troponins in accelerated diagnostic pathways. Practical suggestions are made for laboratories regarding analytical quality assessment of cardiac troponin results at low cutoffs, with a particular focus on accelerated diagnostic pathways. The review also discusses how future use of cardiac troponins for long-term prediction or management of cardiovascular disease may require improvements in analytical quality. SUMMARY: Clinical guidelines recommend using cardiac troponin concentrations as low as the limit of detection of the assay to guide patient care. Laboratories, manufacturers, researchers, and external quality assessment providers should extend analytical performance monitoring of cardiac troponin assays to include the concentration ranges applicable in these pathways.


Asunto(s)
Bioensayo , Infarto del Miocardio , Humanos , Química Clínica , Hospitalización , Infarto del Miocardio/diagnóstico , Troponina
6.
J Am Coll Cardiol ; 82(1): 60-69, 2023 07 04.
Artículo en Inglés | MEDLINE | ID: mdl-37380305

RESUMEN

The term "single-sample rule-out" refers to the ability of very low concentrations of high-sensitivity cardiac troponin (hs-cTn) on presentation to exclude acute myocardial infarction with high clinical sensitivity and negative predictive value. Observational and randomized studies have confirmed this ability. Some guidelines endorse use of a concentration of hs-cTn at the assay's limit of detection, while other studies have validated the use of higher concentrations, allowing this approach to identify a greater proportion of patients at low risk. In most studies, at least 30% of patients can be triaged with this approach. The concentration of hs-cTn varies according to the assay used and sometimes how regulations permit reporting. It is clear that patients need to be at least 2 hours from the onset of symptoms being evaluated. Caution is warranted, particularly with older patients, women, and patients with underlying cardiac comorbidities.


Asunto(s)
Infarto del Miocardio , Humanos , Femenino , Infarto del Miocardio/diagnóstico , Corazón , Triaje , Troponina
7.
Clin Chem Lab Med ; 61(8): 1411-1419, 2023 07 26.
Artículo en Inglés | MEDLINE | ID: mdl-36952681

RESUMEN

The International Federation of Clinical Chemistry Committee on Clinical Applications of Cardiac Biomarkers (IFCC C-CB) provides educational documents to facilitate the interpretation and use of cardiac biomarkers in clinical laboratories and practice. Our aim is to improve the understanding of certain key analytical and clinical aspects of cardiac biomarkers and how these may interplay. Measurements of cardiac troponin (cTn) have a prominent place in the clinical work-up of patients with suspected acute coronary syndrome. It is therefore important that clinical laboratories know how to recognize and assess analytical issues. Two emerging analytical issues resulting in falsely high cTn concentrations, often several fold higher than the upper reference limit (URL), are antibody-mediated assay interference due to long-lived cTn-antibody complexes, called macrotroponin, and crosslinking antibodies that are frequently referred to as heterophilic antibodies. We provide an overview of antibody-mediated cTn assay interference and provide recommendations on how to confirm the interference and interpret the results.


Asunto(s)
Infarto del Miocardio , Humanos , Biomarcadores , Química Clínica , Anticuerpos , Troponina
8.
Clin Chem ; 69(6): 649-660, 2023 06 01.
Artículo en Inglés | MEDLINE | ID: mdl-36994764

RESUMEN

BACKGROUND: Acute chest pain is associated with an increased risk of death and cardiovascular events even when acute myocardial infarction (AMI) has been excluded. Growth differentiation factor-15 (GDF-15) is a strong prognostic marker in patients with acute chest pain and AMI, but the prognostic value in patients without AMI is uncertain. This study sought to investigate the ability of GDF-15 to predict long-term prognosis in patients presenting with acute chest pain without AMI. METHODS: In total, 1320 patients admitted with acute chest pain without AMI were followed for a median of 1523 days (range: 4 to 2208 days). The primary end point was all-cause mortality. Secondary end points included cardiovascular (CV) death, future AMI, heart failure hospitalization, and new-onset atrial fibrillation (AF). RESULTS: Higher concentrations of GDF-15 were associated with increased risk of death from all causes (median concentration in non-survivors vs survivors: 2124 pg/mL vs 852 pg/mL, P < 0.001), and all secondary end points. By multivariable Cox regression, GDF-15 concentration ≥4th quartile (compared to <4th quartile) remained an independent predictor of all-cause death (adjusted hazard ratio (HR): 2.75; 95% CI, 1.69-4.45, P < 0.001), CV death (adjusted HR: 3.74; 95% CI, 1.31-10.63, P = 0.013), and heart failure hospitalization (adjusted HR: 2.60; 95% CI, 1.11-6.06, P = 0.027). Adding GDF-15 to a model consisting of established risk factors and high-sensitivity cardiac troponin T (hs-cTnT) led to a significant increase in C-statistics for prediction of all-cause mortality. CONCLUSIONS: Higher concentrations of GDF-15 were associated with increased risk of mortality from all causes and risk of future CV events.


Asunto(s)
Insuficiencia Cardíaca , Infarto del Miocardio , Humanos , Pronóstico , Factor 15 de Diferenciación de Crecimiento , Biomarcadores , Estudios Prospectivos , Infarto del Miocardio/diagnóstico , Dolor en el Pecho , Insuficiencia Cardíaca/diagnóstico
9.
Clin Chem Lab Med ; 61(6): 989-998, 2023 05 25.
Artículo en Inglés | MEDLINE | ID: mdl-36637984

RESUMEN

The International Federation of Clinical Chemistry and Laboarator Medicine (IFCC) Committee on Clinical Applications of Cardiac Bio-Markers (C-CB) has provided evidence-based educational resources to aid and improve the understanding of important analytical and clinical aspects of cardiac biomarkers. The present IFCC C-CB educational report focuses on recommendations for appropriate use, analytical performance, and gaps in clinical studies related to the use of cardiac troponin (cTn) by point of care (POC) measurement, often referred to as a point of care testing (POCT). The use of high-sensitivity (hs)-cTn POC devices in accelerated diagnostic protocols used in emergency departments or outpatient clinics investigating acute coronary syndrome has the potential for improved efficacy, reduction of length of stay and reduced costs in the health care system. POCT workflow integration includes location of the instrument, assignment of collection and testing responsibility to (non-lab) staff, instrument maintenance, in-service and recurrent training, quality control, proficiency assessments, discrepant result trapping, and troubleshooting and inventory management.


Asunto(s)
Síndrome Coronario Agudo , Sistemas de Atención de Punto , Humanos , Biomarcadores , Síndrome Coronario Agudo/diagnóstico , Química Clínica , Troponina , Troponina T
10.
Clin Chem ; 68(8): 1022-1030, 2022 07 27.
Artículo en Inglés | MEDLINE | ID: mdl-35716089

RESUMEN

The International Federation of Clinical Chemistry Committee on Clinical Application of Cardiac Bio-Markers provides evidence-based educational documents to facilitate uniform interpretation and utilization of cardiac biomarkers in clinical laboratories and practice. The committee's goals are to improve the understanding of certain key analytical and clinical aspects of cardiac biomarkers and how these may interplay in clinical practice. Measurement of high-sensitivity cardiac troponin (hs-cTn) assays is a cornerstone in the clinical evaluation of patients with symptoms and/or signs of acute cardiac ischemia. To define myocardial infarction, the Universal Definition of Myocardial Infarction requires patients who manifest with features suggestive of acute myocardial ischemia to have at least one cTn concentration above the sex-specific 99th percentile upper reference limit (URL) for hs-cTn assays and a dynamic pattern of cTn concentrations to fulfill the diagnostic criteria for MI. This special report provides an overview of how hs-cTn 99th percentile URLs should be established, including recommendations about prescreening and the number of individuals required in the reference cohort, how statistical analysis should be conducted, optimal preanalytical and analytical protocols, and analytical/biological interferences or confounds that can affect accurate determination of the 99th percentile URLs. This document also provides guidance and solutions to many of the issues posed.


Asunto(s)
Infarto del Miocardio , Isquemia Miocárdica , Bioensayo , Biomarcadores , Química Clínica , Femenino , Humanos , Masculino , Infarto del Miocardio/diagnóstico , Troponina/análisis , Troponina T
11.
Eur Heart J Acute Cardiovasc Care ; 11(3): 201-212, 2022 Mar 16.
Artículo en Inglés | MEDLINE | ID: mdl-35024819

RESUMEN

AIMS: This study tested the hypothesis that combining stress-induced biomarkers (copeptin or glucose) with high-sensitivity cardiac troponin (hs-cTn) increases diagnostic accuracy for non-ST-elevation myocardial infarction (NSTEMI) in patients presenting to the emergency department. METHODS AND RESULTS: The ability to rule-out NSTEMI for combinations of baseline hs-cTnT or hs-cTnI with copeptin or glucose was compared with the European Society of Cardiology (ESC) hs-cTnT/I-only rule-out algorithms in two independent (one Norwegian and one international multicentre) diagnostic studies. Among 959 patients (median age 64 years, 60.5% male) with suspected NSTEMI in the Norwegian cohort, 13% had NSTEMI. Adding copeptin or glucose to hs-cTnT/I as a continuous variable did not improve discrimination as quantified by the area under the curve {e.g. hs-cTnT/copeptin 0.91 [95% confidence interval (CI) 0.89-0.93] vs. hs-cTnT alone 0.91 (95% CI 0.89-0.93); hs-cTnI/copeptin 0.85 (95% CI 0.82-0.87) vs. hs-cTnI alone 0.93 (95% CI 0.91-0.95)}, nor did adding copeptin <9 mmol/L or glucose <5.6 mmol/L increase the sensitivity of the rule-out provided by hs-cTnT <5 ng/L or hs-cTnI <4 ng/L in patients presenting more than 3 h after chest pain onset (target population in the ESC-0 h-algorithm). The combination decreased rule-out efficacy significantly (both P < 0.01). These findings were confirmed among 1272 patients (median age 62 years, 69.3% male) with suspected NSTEMI in the international validation cohort, of which 20.7% had NSTEMI. A trend towards increased sensitivity for the hs-cTnT/I/copeptin combinations (97-100% vs. 91-97% for the ESC-0 h-rule-out cut-offs) was observed in the Norwegian cohort. CONCLUSION: Adding copeptin or glucose to hs-cTnT/I did not increase diagnostic performance when compared with current ESC guideline hs-cTnT/I-only 0 h-algorithms.


Asunto(s)
Infarto del Miocardio , Infarto del Miocardio sin Elevación del ST , Biomarcadores , Femenino , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio/diagnóstico , Infarto del Miocardio sin Elevación del ST/diagnóstico , Estudios Prospectivos , Troponina I , Troponina T
12.
Clin Chem Lab Med ; 60(4): 576-583, 2022 03 28.
Artículo en Inglés | MEDLINE | ID: mdl-34162037

RESUMEN

OBJECTIVES: Cardiac myosin-binding protein C (cMyC) is a novel biomarker of myocardial injury, with a promising role in the triage and risk stratification of patients presenting with acute cardiac disease. In this study, we assess the weekly biological variation of cMyC, to examine its potential in monitoring chronic myocardial injury, and to suggest analytical quality specification for routine use of the test in clinical practice. METHODS: Thirty healthy volunteers were included. Non-fasting samples were obtained once a week for ten consecutive weeks. Samples were tested in duplicate on the Erenna® platform by EMD Millipore Corporation. Outlying measurements and subjects were identified and excluded systematically, and homogeneity of analytical and within-subject variances was achieved before calculating the biological variability (CVI and CVG), reference change values (RCV) and index of individuality (II). RESULTS: Mean age was 38 (range, 21-64) years, and 16 participants were women (53%). The biological variation, RCV and II with 95% confidence interval (CI) were: CVA (%) 19.5 (17.8-21.6), CVI (%) 17.8 (14.8-21.0), CVG (%) 66.9 (50.4-109.9), RCV (%) 106.7 (96.6-120.1)/-51.6 (-54.6 to -49.1) and II 0.42 (0.29-0.56). There was a trend for women to have lower CVG. The calculated RCVs were comparable between genders. CONCLUSIONS: cMyC exhibits acceptable RCV and low II suggesting that it could be suitable for disease monitoring, risk stratification and prognostication if measured serially. Analytical quality specifications based on biological variation are similar to those for cardiac troponin and should be achievable at clinically relevant concentrations.


Asunto(s)
Proteínas Portadoras , Proteínas del Citoesqueleto , Troponina I , Adulto , Biomarcadores , Femenino , Humanos , Masculino , Persona de Mediana Edad , Valores de Referencia , Adulto Joven
13.
Clin Chem ; 68(2): 291-302, 2022 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-34897415

RESUMEN

BACKGROUND: The European Society of Cardiology (ESC) rule-out algorithms use cutoffs optimized for exclusion of non-ST elevation myocardial infarction (NSTEMI). We investigated these and several novel algorithms for the rule-out of non-ST elevation acute coronary syndrome (NSTE-ACS) including less urgent coronary ischemia. METHOD: A total of 1504 unselected patients with suspected NSTE-ACS were included and divided into a derivation cohort (n = 988) and validation cohort (n = 516). The primary endpoint was the diagnostic performance to rule-out NSTEMI and unstable angina pectoris during index hospitalization. The secondary endpoint was combined MI, all-cause mortality (within 30 days) and urgent (24 h) revascularization. The ESC algorithms for high-sensitivity cardiac troponin T (hs-cTnT) and I (hs-cTnI) were compared to different novel low-baseline (limit of detection), low-delta (based on the assay analytical and biological variation), and 0-1-h and 0-3-h algorithms. RESULTS: The prevalence of NSTE-ACS was 24.8%, 60.0% had noncardiac chest pain, and 15.2% other diseases. The 0-1/0-3-h algorithms had superior clinical sensitivity for the primary endpoint compared to the ESC algorithm (validation cohort); hs-cTnT: 95% vs 63%, and hs-cTnI: 87% vs 64%, respectively. Regarding the secondary endpoint, the algorithms had similar clinical sensitivity (100% vs 94%-96%) but lower clinical specificity (41%-19%) compared to the ESC algorithms (77%-74%). The rule-out rates decreased by a factor of 2-4. CONCLUSION: Low concentration/low-delta troponin algorithms improve the clinical sensitivity for a combined endpoint of NSTEMI and unstable angina pectoris, with the cost of a substantial reduction in total rule-out rate. There was no clear benefit compared to ESC for diagnosing high-risk events.


Asunto(s)
Síndrome Coronario Agudo , Infarto del Miocardio , Infarto del Miocardio sin Elevación del ST , Síndrome Coronario Agudo/diagnóstico , Algoritmos , Angina Inestable/diagnóstico , Biomarcadores , Humanos , Infarto del Miocardio/diagnóstico , Infarto del Miocardio sin Elevación del ST/diagnóstico , Troponina I , Troponina T
14.
Clin Biochem ; 98: 74-77, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34624255

RESUMEN

BACKGROUND: Secretoneurin is a novel prognostic biomarker that may predict mortality in heart failure and the occurrence of ventricular arrhythmias. This study reports the within subject variation (CVI), between subject variation (CVG), reference change values (RCV) and index of individuality (II) of secretoneurin. METHODS: Thirty healthy volunteers were included. Non-fasting samples were obtained between 8 and 10 am once a week for ten weeks. Secretoneurin was analyzed in duplicate using ELISA. No outliers were present according to Burnett and Reeds' criteria. Simple linear regression did not identify significant trends. Variance homogeneity in the analytical variance and CVI were tested using Cochrane's and Bartlett's tests and four participants were excluded. Calculation of CVI, CVG and RCV were done on ln transformed data as described by Fokkema, the II was calculated using retransformed data. RESULTS: The median age of the participants was 36 years and 53% were female. Non-fasting glucose, eGFR(CKD-EPI), cTnT and NT-proBNP concentrations were within the normal range. Median secretoneurin concentrations were 38 pmol/L (women) and 33 pmol/L (men), p-value < 0.001. CVI and CVG were 9.8% (CI 8.7% to 11.0%) and 20.0 (CI 15.4% to 28.0%), respectively. RCV were 38.7% (CI 35.5% to 42.7%) and -27.9 (CI -29.9 to -26.2) and the II were 0.60 (CI 0.42-0.78). No gender differences were present. CONCLUSION: Secretoneurin has a fairly low CVI, CVG, RCV and II, indicating that it could be suitable as a diagnostic or prognostic biomarker and that delta values in serial samplings may be preferable for identifying clinical changes.


Asunto(s)
Arritmias Cardíacas/sangre , Neuropéptidos/sangre , Secretogranina II/sangre , Adulto , Arritmias Cardíacas/diagnóstico , Biomarcadores/sangre , Femenino , Humanos , Masculino , Persona de Mediana Edad , Pronóstico
15.
Clin Chem ; 67(8): 1144-1152, 2021 08 05.
Artículo en Inglés | MEDLINE | ID: mdl-34061171

RESUMEN

BACKGROUND: The CARdiac MARker Guideline Uptake in Europe (CAMARGUE) program is a multi-country audit of the use of cardiac biomarkers in routine clinical practice. METHODS: An email link to a web-based questionnaire of 30 multiple-choice questions was distributed via the professional societies in Europe. RESULTS: 374 questionnaires were returned from 39 countries, the majority of which were in northern Europe with a response rate of 8.2%-42.0%. The majority of the respondents were from hospitals with proportionately more responses from central hospitals than district hospitals. Cardiac troponin was the preferred cardiac biomarker, evenly split between cardiac troponin T (cTnT) and cardiac troponin I (cTnI). Aspartate transaminase and lactate dehydrogenase are no longer offered as cardiac biomarkers. Creatine kinase, creatine kinase MB isoenzyme, and myoglobin continue to be offered as part of the cardiac biomarker profile in approximately on 50% of respondents. There is widespread utilization of high sensitivity (hs) troponin assays. The majority of cTnT users measure hs-cTnT. 29.5% of laboratories measure cTnI by a non-hs method but there has been substantial conversion to hs-cTnI. The majority of respondents used ng/L and use the 99th percentile as the upper reference limit (71.9% of respondents). A range of diagnostic protocols are in use. CONCLUSIONS: There is widespread utilization of hs troponin methods. A significant minority do not use the 99th percentile as recommended and there is, as yet, little uptake of very rapid diagnostic strategies. Education of laboratory professionals and clinicians remains a priority.


Asunto(s)
Laboratorios , Troponina T , Biomarcadores , Forma MB de la Creatina-Quinasa , Humanos , Troponina I
16.
J Int Soc Sports Nutr ; 18(1): 51, 2021 Jun 28.
Artículo en Inglés | MEDLINE | ID: mdl-34183020

RESUMEN

BACKGROUND: Dietary supplement use among recreational athletes is common, with the intention of reducing inflammation and improving recovery. We aimed to describe the relationship between omega-3 fatty acid supplement use and inflammation induced by strenuous exercise. METHODS: C-reactive protein (CRP) concentrations were measured in 1002 healthy recreational athletes before and 24 h after a 91-km bicycle race. The use of omega-3 fatty acid supplements was reported in 856 out of 1002 recreational athletes, and the association between supplement use and the exercise-induced CRP response was assessed. RESULTS: Two hundred seventy-four subjects reported regular use of omega-3 fatty acid supplements. One hundred seventy-three of these used cod liver oil (CLO). Regular users of omega-3 fatty acid supplements had significantly lower basal and exercise-induced CRP levels as compared to non-users (n = 348, p < 0.001). Compared to non-users, regular users had a 27% (95% confidence interval (CI): 14-40) reduction in Ln CRP response (unadjusted model, p < 0.001) and 16% (95% CI: 5-28, p = 0.006) reduction after adjusting for age, sex, race duration, body mass index, delta creatine kinase, MET hours per week, resting heart rate and higher education. CLO was the primary driver of this response with a 34% (95% CI: 19-49) reduction (unadjusted model, p < 0.001) compared to non-users. Corresponding numbers in the adjusted model were 24% (95% CI: 11-38, p < 0.001). CONCLUSION: Basal CRP levels were reduced, and the exercise-induced CRP response was attenuated in healthy recreational cyclists who used omega-3 fatty acid supplements regularly. This effect was only present in regular users of CLO. TRIAL REGISTRATION: NCT02166216 , registered June 18, 2014 - Retrospectively registered.


Asunto(s)
Proteína C-Reactiva/análisis , Aceite de Hígado de Bacalao/administración & dosificación , Ejercicio Físico/fisiología , Vitaminas/administración & dosificación , Adulto , Ciclismo/fisiología , Intervalos de Confianza , Creatina Quinasa/sangre , Ácidos Grasos Omega-3/administración & dosificación , Femenino , Frecuencia Cardíaca/fisiología , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos
18.
Eur Heart J Acute Cardiovasc Care ; 10(3): 287-301, 2021 May 11.
Artículo en Inglés | MEDLINE | ID: mdl-33620429

RESUMEN

AIMS: Troponin-based algorithms are made to identify myocardial infarctions (MIs) but adding either standard acute coronary syndrome (ACS) risk criteria or a clinical risk score may identify more patients eligible for early discharge and patients in need of urgent revascularization. METHODS AND RESULTS: Post-hoc analysis of the WESTCOR study including 932 patients (mean 63 years, 61% male) with suspected NSTE-ACS. Serum samples were collected at 0, 3, and 8-12 h and high-sensitivity cTnT (Roche Diagnostics) and cTnI (Abbott Diagnostics) were analysed. The primary endpoint was MI, all-cause mortality, and unplanned revascularizations within 30 days. Secondary endpoint was non-ST-elevation myocardial infarction (NSTEMI) during index hospitalization. Two combinations were compared: troponin-based algorithms (ESC 0/3 h and the High-STEACS algorithm) and either ACS risk criteria recommended in the ESC guidelines, or one of eleven clinical risk scores, HEART, mHEART, CARE, GRACE, T-MACS, sT-MACS, TIMI, EDACS, sEDACS, Goldman, and Geleijnse-Sanchis. The prevalence of primary events was 21%. Patients ruled out for NSTEMI and regarded low risk of ACS according to ESC guidelines had 3.8-4.9% risk of an event, primarily unplanned revascularizations. Using HEART score instead of ACS risk criteria reduced the number of events to 2.2-2.7%, with maintained efficacy. The secondary endpoint was met by 13%. The troponin-based algorithms without evaluation of ACS risk missed three-index NSTEMIs with a negative predictive value (NPV) of 99.5% and 99.6%. CONCLUSION: Combining ESC 0/3 h or the High-STEACS algorithm with standardized clinical risk scores instead of ACS risk criteria halved the prevalence of rule-out patients in need of revascularization, with maintained efficacy.


Asunto(s)
Síndrome Coronario Agudo , Síndrome Coronario Agudo/diagnóstico , Síndrome Coronario Agudo/epidemiología , Biomarcadores , Femenino , Humanos , Masculino , Factores de Riesgo , Troponina I , Troponina T
19.
J Am Heart Assoc ; 9(23): e017465, 2020 12.
Artículo en Inglés | MEDLINE | ID: mdl-33238783

RESUMEN

Background Cardiac troponin (cTn) permits early rule-out/rule-in of patients admitted with possible non-ST-segment-elevation myocardial infarction. In this study, we developed an admission and a 0/1 hour rule-out/rule-in algorithm for a troponin assay with measurable results in >99% of healthy individuals. We then compared its diagnostic and long-term prognostic properties with other protocols. Methods and Results Blood samples were collected at 0, 1, 3, and 8 to 12 hours from patients admitted with possible non-ST-segment-elevation myocardial infarction. cTnT (Roche Diagnostics), cTnI(Abbott) (Abbott Diagnostics), and cTnI(sgx) (Singulex Clarity System) were measured in 971 admission and 465 1-hour samples. An admission and a 0/1 hour rule-out/rule-in algorithm were developed for the cTnI(sgx) assay and its diagnostic properties were compared with cTnTESC (European Society of Cardiology), cTnI(Abbott)ESC, and 2 earlier cTnI(sgx) algorithms. The prognostic composite end point was all-cause mortality and future nonfatal myocardial infarction during a median follow-up of 723 days. non-ST-segment-elevation myocardial infarction prevalence was 13%. The novel cTnI(sgx) algorithms showed similar performance regardless of time from symptom onset, and area under the curve was significantly better than comparators. The cTnI(sgx)0/1 hour algorithm classified 92% of patients to rule-in or rule-out compared with ≤78% of comparators. Patients allocated to rule-out by the prior published 0/1 hour algorithms had significantly fewer long-term events compared with the rule-in and observation groups. The novel cTnI(sgx)0/1 hour algorithm used a higher troponin baseline concentration for rule-out and did not allow for prognostication. Conclusions Increasingly sensitive troponin assays may improve identification of non-ST-segment-elevation myocardial infarction but could rule-out patients with subclinical chronic myocardial injury. Separate protocols for diagnosis and risk prediction seem appropriate.


Asunto(s)
Infarto del Miocardio sin Elevación del ST/sangre , Infarto del Miocardio sin Elevación del ST/diagnóstico , Troponina I/sangre , Troponina T/sangre , Anciano , Algoritmos , Biomarcadores , Estudios Transversales , Femenino , Hospitalización , Humanos , Masculino , Persona de Mediana Edad , Infarto del Miocardio sin Elevación del ST/mortalidad , Valor Predictivo de las Pruebas , Pronóstico , Curva ROC , Tasa de Supervivencia , Factores de Tiempo
20.
Clin Chim Acta ; 511: 59-66, 2020 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-33002472

RESUMEN

BACKGROUND: The European Federation of Clinical Chemistry and Laboratory Medicine (EFLM) initiated the CArdiac MARker Guidelines Uptake in Europe (CAMARGUE) Study to survey if current biomarker testing for heart failure (HF) in Europe is in accordance with up-dated guidelines. METHODS: A web-based questionnaire was distributed to clinical laboratories via European biochemical societies in 2019. Questions covered the type of natriuretic peptide (NP) assays performed, decision limits for HF, and opinion concerning requirement of different thresholds in patients with renal failure or obesity. RESULTS: There were 347 participating laboratories mostly from European countries with 266 offering NP testing. NP testing was increased from 67% to 77% between 2013 and 2019. NT-proBNP remained the preferred biomarker. Recommended decision limits were implemented for BNP (85%) and better focused for NT-proBNP (40%) than in the previous survey. The survey revealed that laboratorians are willing to support the translation of adjusted cut-off values for age, gender and for patients with conditions like renal insufficiency. CONCLUSION: Guidelines stimulate clinical laboratories to offer NP testing with high value for the diagnosis and management of HF, and to present adjusted medical decision limits. Future guidelines should encourage the use of personalized cut-offs for some confounding factors.


Asunto(s)
Insuficiencia Cardíaca , Laboratorios , Biomarcadores , Europa (Continente) , Insuficiencia Cardíaca/diagnóstico , Humanos , Péptido Natriurético Encefálico , Fragmentos de Péptidos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...